POWER YOUR BUSINESS!
CHARGE UP YOUR DAY!
ELECTRIFY YOUR MOBILITY
Authorisation |
Autostart (without access protection) RFID Backend |
---|---|
Load management |
Downgrade input Static load management Dynamic load management Connection to an external EMS via Modbus TCP and EEBus |
Networking |
via LAN to external energy management system via LAN to Professional charging systems |
Protocol backend communication |
OCPP 1.5s OCPP 1.6j OCPP 1.6s |
Interface backend communication |
via mobile radio via LAN |
Communication with vehicle |
IEC 61851-1 Mode 3 |
Product colour |
light gray (RAL 7035) |
Connection |
1 -phase 3 -phase |
---|---|
Maximum charging power per charging point |
22 kW |
Personal protection |
40 / 0,03A, 4p, type A |
Line protection |
C-32A, 3p+N, 10kA |
Electricity meter (MID compliant) |
yes (readable from outside) |
Integrated power meter |
yes |